Part 11 essentials
- Validated systems: accurate, reliable and performing as intended (11.10(a)).
- Secure, computer-generated, time-stamped audit trails of entries and of actions that create, modify or delete records; changes must not obscure earlier entries (11.10(e)).
- Records protected so they can be retrieved accurately throughout the retention period (11.10(c)).
- Access limited to authorized individuals (11.10(d)).
- Electronic signatures unique to one person and never reused or reassigned (11.100).
What an audit trail entry should show
Who made the change, when, what changed, the old and new values, and why. The reason for change is a GCP expectation rather than Part 11 text.
ALCOA++ data integrity
Attributable, Legible, Contemporaneous, Original, Accurate, Complete, Consistent, Enduring, Available and Traceable, as listed in EMA’s 2023 guideline.
Good practice
- Edit checks and range checks at the point of entry.
- Systematic query management.
- A formal database lock before analysis.
- Secure, validated methods for exports and transfers.
- Record retention under 21 CFR 312.62(c): 2 years after a marketing application is approved for the indication studied. If no application will be filed, or it is not approved for that indication, 2 years after the investigation is discontinued and FDA is notified. Device studies follow 21 CFR 812.140(d). Agreements or institutional policy may require longer.
Common violations
- Backdating entries.
- Shared logins.
- Changes made without an audit trail.
- Users not trained on the system.
- No documented reason for a change.
Checklist
Electronic system readiness
- System validation documented
- Secure, computer-generated, time-stamped audit trail
- A unique account for every user; no shared logins
- Role-based access, reviewed whenever staff change
- E-signatures unique, never reused or reassigned
- Backup and retrieval tested for the full retention period
- A validated export method for database lock and archive
Practice with KLINiLEARN
Test yourself on this topic
- Module 1: Data integrity principlesData Integrity and Electronic Records, free practice course
- Module 2: Part 11 scope and system controlsData Integrity and Electronic Records, free practice course
- Module 3: Electronic signaturesData Integrity and Electronic Records, free practice course
- Module 4: Electronic systems in trialsData Integrity and Electronic Records, free practice course
- Module 5: eSource, corrections and retentionData Integrity and Electronic Records, free practice course
ILO, our clinical trial platform, is designed for 21 CFR Part 11, with audit trails, role-based access, electronic signatures and secure archival. About ILO
Sources
- 21 CFR Part 11: Electronic Records; Electronic Signatures
- 21 CFR 11.10: Controls for closed systems
- FDA guidance: Part 11, Scope and Application (2003)
- EMA guideline on computerised systems and electronic data in clinical trials (2023)
- 21 CFR 312.62: Investigator recordkeeping and record retention
- 21 CFR 812.140: Records (device studies)
- FDA guidance: Electronic Systems, Electronic Records, and Electronic Signatures in Clinical Investigations, Questions and Answers (October 2024)
General guidance only. Always check the current regulations and your protocol.