Module 5 of 5

eSource, corrections and retention

eSource, investigator sign-off, certified copies and how long records are kept.

Lecture for Module 5. Open the playlist on YouTube

Key points

  • Every data element has an originator: a person, system, device or instrument (FDA eSource guidance).
  • The investigator reviews and electronically signs the eCRF before data are archived or submitted (III.B.1).
  • Changes after sign-off are reviewed and signed by the investigator (III.B.2).
  • Records are protected for accurate and ready retrieval throughout retention (11.10(c)).
  • Retention periods come from predicate rules such as 312.62(c) and 812.140(d).
  • The sponsor should not have exclusive control of trial data (E6(R3) Annex 1 3.16.1(l)).

Reading for this module

Module 5 quiz

10 questions. Pass mark: 9 of 10. Questions and answers are shuffled each time, and you see the explanations when you finish.