Module 5 of 5
QT prolongation and cardiac safety
QT prolongation, the thorough QT study and concentration-QTc analysis under ICH E14.
Lecture for Module 5. Open the playlist on YouTube
Key points
- QT prolongation can be associated with torsade de pointes.
- QT is corrected for heart rate, for example with Fridericia's formula (QT divided by the cube root of RR).
- The threshold of regulatory concern is around 5 ms.
- A negative thorough QT study excludes 10 ms with the upper bound of the one-sided 95 percent interval.
- A positive control shows assay sensitivity: the study can detect an effect of about 5 ms.
- Concentration-QTc analysis of early-phase data can replace a thorough QT study (E14/S7B Q&As R1).
Reading for this module
- ICH E14, Clinical Evaluation of QT/QTc Interval Prolongation (FDA copy)The thorough QT/QTc study and ECG assessment.
- ICH E14/S7B Questions and Answers (R1) (ICH, 20 August 2026; FDA, October 2026)Concentration-QTc modeling as an alternative.
Module 5 quiz
10 questions. Pass mark: 9 of 10. Questions and answers are shuffled each time, and you see the explanations when you finish.